Bioassay

Research and validation of new carrier matrix of iCIEF method for charge heterogeneity analysis of recombinant bispecific antibody

Expand
  • The Institute of Biotechnology Development, Qilu Pharmaceutical Co., Ltd., Jinan 25100, China

Received date: 2022-07-21

  Online published: 2024-06-25

Abstract

Objective: To develop a method with new carrier matrix for the detection of charge heterogeneity of recombinant bispecific antibody(bsAb) by imaging capillary isoelectric focusing electrophoresis(iCIEF). Methods: Firstly, the separation efficiency of charge heterogeneity of two bispecific antibodies products in the traditional carrier matrix methyl cellulose(MC)/hydroxypropyl methyl cellulose(HPMC) and glycerol matrix was compared. Subsequently, the method of glycerol matrix was further optimized to study the effects of glycerol concentration, ampholyte brand and its final concentration, and the combination of ampholyte in different pH ranges on the separation effect of the two bsAbs charge isomers, so as to obtain the best analytical conditions based on glycerol matrix.Finally, the iCIEF method was verified by the optimal separation conditions of glycerol matrix,and the validation indexes included precision, accuracy, linearity range and stability indicator test. Results: The separation efficiency of charge isomers of the two bispecific antibodies in glycerol matrix was better than that in HPMC carrier matrix and the method had good robustness. The results of the method validation showed that for bsAb 1, the RSD of the peak area percentages of acid region, the main peak and the base region were all less than 2.0%, and the precision was good. In the final protein concentration range of 0.10-0.30 mg·mL-1, the r score of the linear regression cure of the main peak was greater than 0.99, and the linearity was good; the recovery rate of each concentration was in the range of 95%-105%, and the accuracy was good. For bsAb 2, the RSD of peak area percentages of acid region and main peak were less than 2.0%, and the peak area percentage of base region was less than 20.0%, the precision was good. This method could indicate the change of the content of charge variants of the products, and could be used for quality control of products. Conclusion: Using glycerol as a new carrier matrix instead of the traditional carrier matrix for iCIEF analysis has the advantages of good separation efficiency, strong stability, good accuracy and low cost. It solves the problem that the recombinant bispecific antibody drugs with more complex structure can not achieve good separation of charge heterogeneity in traditional MC/HPMC carrier matrix. It is suitable for the quality evaluation and quality control of complex bispecific antibody drugs.

Cite this article

BU Ling-li, ZHANG Rui-ning, HAN Guo-hua, LIU Zhen-dong, WANG Qing-min . Research and validation of new carrier matrix of iCIEF method for charge heterogeneity analysis of recombinant bispecific antibody[J]. Chinese Journal of Pharmaceutical Analysis, 2022 , 42(11) : 1927 -1935 . DOI: 10.16155/j.0254-1793.2022.11.08

References

[1] CHUNG S, TIAN J, TAN Z, et al. Industrial bioprocessing perspectives on managing therapeutic protein charge variant profiles[J].Biotechnol Bioeng, 2018, 115(7):1646
[2] SALAS-SOLANO O, KENNEL B, PARK SS, et al. Robustness of iCIEF methodology for the analysis of monoclonal antibodies: an interlaboratory study[J].J Sep Sci, 2012, 35(22):3124
[3] RUSTANDI RR, PEKLANSKY B, ANDERSON CL. Use of imaged capillary isoelectric focusing technique in development of diphtheria toxin mutant CRM197[J].Electrophoresis, 2014, 35(7):1065
[4] WU G, YU C, WANG W, et al. Interlaboratory method validation of iCIEF methodology for analysis of monoclonal antibodies[J].Electrophoresis, 2018, 39(16):2091
[5] SOMAN G, KALLARAKAL AT, MICHIEL D, et al. Analytical characterization of ch14.18: a mouse-human chimeric disialoganglioside-specific therapeutic antibody[J].MAbs, 2012, 4(1):84
[6] GERVAIS D, KING D. Capillary isoelectric focusing of a difficult-to-denature tetrameric enzyme using alkylurea-urea mixtures[J].Anal Biochem, 2014, 465:90
[7] ZHANG X, VORONOV S, MUSSA N, et al. A novel reagent significantly improved assay robustness in imaged capillary isoelectric focusing[J].Anal Biochem, 2017, 521:1
[8] ZHANG X, CHEMMALIL L, DING J, et al. Imaged capillary isoelectric focusing in native condition: a novel and successful example[J].Anal Biochem, 2017, 537:13
[9] KONTERMANN RE, BRINKMANN U. Bispecific antibodies[J].Drug Discov Today, 2015, 20(7):838
[10] DAI J, LAMP J, XIA Q, et al. Capillary isoelectric focusing-mass spectrometry method for the separation and online characterization of intact monoclonal antibody charge variants[J].Anal Chem, 2018, 90(3):2246
[11] LECOEUR M, GAREIL P, VARENNE A. Separation and quantitation of milk whey proteins of close isoelectric points by on-line capillary isoelectric focusing-electrospray ionization mass spectrometry in glycerol-water media[J].J Chromatogr A, 2010, 1217(46):7293
[12] PRZYBYLSKI C, MOKADDEM M, PRULL-JANSSEN M, et al. On-line capillary isoelectric focusing hyphenated to native electrospray ionization mass spectrometry for the characterization of interferon-γ and variants[J].Analyst, 2015, 140(2):543
[13] MOKADDEM M, GAREIL P, VARENNE A. Online CIEF-ESI-MS in glycerol-water media with a view to hydrophobic protein applications[J].Electrophoresis, 2009, 30(23):4040
[14] BUSNEL JM, VARENNE A, DESCROIX S, et al. Evaluation of capillary isoelectric focusing in glycerol-water media with a view to hydrophobic protein applications[J].Electrophoresis, 2005, 26(17):3369
[15] DU Y, WALSH A, EHRICK R, et al. Chromatographic analysis of the acidic and basic species of recombinant monoclonal antibodies[J].MAbs, 2012, 4(5):578
[16] ANTES B, AMON S, RIZZI A, et al. Analysis of lysine clipping of a humanized Lewis-Y specific IgG antibody and its relation to Fc-mediated effector function[J].J Chromatogr B Analyt Technol Biomed Life Sci, 2007, 852(1-2):250
[17] SCALLON BJ, TAM SH, MCCARTHY SG, et al. Higher levels of sialylated Fc glycans in immunoglobulin G molecules can adversely impact functionality[J].Mol Immunol, 2007, 44(7):1524
[18] 于传飞, 郭玮, 王兰, 等. 成像毛细管等点聚焦电泳法对单克隆抗体制品的电荷异质性分析[J].药物分析杂志, 2014, 34(7):1212
YU CF, GUO W, WANG L, et al. Charge heterogeneity analysis of monoclonal antibody products with imaging capillary isoelectric focusing electrophoresis[J].Chin J Pharm Anal, 2014, 34(7):1212
[19] 于传飞, 王文波, 刘春雨, 等. 离子交换色谱对抗VEGFR2单抗的电荷异质性分析[J].微生物学免疫学进展, 2014, 42(5):17
YU CF, WANG WB, LIU CY, et al. Analysis of charge heterogeneity for anti-VEGFR2 monoclonal antibody by CEX-HPLC[J].Prog Microbiol Immunol, 2014, 42(5):17
[20] SREBALUS B, CATHERINE A, LIM A. Applications of mass spectrometry for the structural characterization of recombinant protein pharmaceuticals[J].Mass Spectrom Rev, 2007, 26(3):370
[21] DADA OO, JAYA N, VALLIERE-DOUGLASS J, et al. Characterization of acidic and basic variants of IgG1 therapeutic monoclonal antibodies based on non-denaturing IEF fractionation[J].Electrophoresis, 2015, 36(21-22):2695
[22] MEERT CD, BRADY LJ, GUO A, et al. Characterization of antibody charge heterogeneity resolved by preparative immobilized pH gradients[J].Anal Chem, 2010, 82(9):3510
[23] HOSKEN BD, LI C, MULLAPPALLY B, et al. Isolation and characterization of monoclonal antibody charge variants by free flow isoelectric focusing[J].Anal Chem, 2016, 88(11):5662
Outlines

/