Objective: To establish limits and method for assay determination of 17 elemental impurities (Al、Cd、Cr、Cu、Fe、Pb、Mn、Hg、Mo、Ni、Sn、Zn、As、Co、V、 Sb、 Li) in methylene blue API in terms of the latest requirement of ICH Q3D, along with quality specification of methylene blue in EP and USP. Methods: Samples were analyzed by inductively coupled plasma mass spectroscopy (ICP-MS) after microwave digestion. The measuring mode was collision mode with He as the collision gas. The RF power was 1 550 W and the plasma gas flow was 15.0 L·min-1. The carrier gas was 1.05 L·min-1. The temperature of atomizing chamber was 2 ℃. The acquiring mode was jumping peak mode and the analytical mode was KED mode. The quantitative method was standard curve calibration corrected by internal standard. Results: The results of analytical method validation indicated that response of nitric acid solution and reagent blank solution was far lower than that of 30% limit solution, which demonstrated there was no quantitative interference.All the calibration curves of elemental impurities showed good linearity in the test concentration range(25%-200% limit concentration, r>0.999). Limits of detection (LOD) were 0.002-1.507 μg·g-1 and limits of quantitation (LOQ) were 0.006-4.567 μg·g-1. The spike recoveries were 82.4%-111.7%. The RSD of repeatability and intermediate precision were 1.1%-4.1% and 1.5%-6.0%, respectively. All results of validation were complied with the requirements of USP <233> and USP<730>. The assays of 17 element impurities in 3 batches of samples were all lower than the 30% limit,which satisfied the requirement of control threshold for elemental impurities in ICH Q3D. Conclusion: The established method is simple in operation, rapid in analysis, sensitive, accurate and precise, which is applicable for the quality control of 17 elemental impurities in methylene blue APIs.
LI Hao, GUAN Qing-lei, ZHENG Wen-feng, MA Li-bo
. Assay determination of 17 elemental impurities in methylene blue APIs[J]. Chinese Journal of Pharmaceutical Analysis, 2022
, 42(11)
: 1954
-1960
.
DOI: 10.16155/j.0254-1793.2022.11.12
[1] 李舸远, 陈东亚,许高山,等.亚甲蓝注射液含量测定取样方法的研究[J].海峡药学, 2018, 30(4): 60
LI GY, CHEN DY, YU GS, et al. Research of sampling methods for assay of methylthioniium chloride injection[J].Strait Pharm J, 2018, 30(4): 60
[2] 杨卓, 刘绍璞, 刘忠芳, 等. 某些酸性三苯甲烷染料与阳离子表面活性剂相互作用的共振瑞利散射光谱及其分析应用[J].高等学校化学学报, 2004, 25(6): 1040
YANG Z, LIU SP, LIU ZF, et al. Resonance rayleigh scattering spectra of interaction of trace amounts of cationic surfactants with some acidic triphenylmethane dyes and their analytical applications[J].Chem J Chin Univ, 2004, 25(6): 1040
[3] 韩淑芹. HPLC法测定亚甲蓝注射液含量及其有关物质[J].中国药师, 2016, 19 (4): 811
HAN SQ. Determination of content and related substances of methylthioinium chloride injection by HPLC[J].China Pharm,2016, 19 (4): 811
[4] 杨瑞,王淑君,周国勤,等.RP-HPLC法测定亚甲蓝微乳中主药的含量[J].中国药房, 2009, 20(4):296
YANG R, WANG SJ, ZHOU GQ, et al. Content determination of main components in methylene blue microemulsions by RP-HPLC[J].China Pharm, 2009, 20(4): 296
[5] 唐良振,李贵芹,王运红,等. 复方亚甲蓝注射液在乳腺脓肿术后切口镇痛中的疗效观察[J].中国当代医药,2016,23(28): 135
TANG LZ, LI GQ, WANG YH, et al. Curative effect observation of compound methylene blue injection in the analgesia of postoperative breast abscess incision[J].China Mod Med, 2016,23(28): 135
[6] EP 10.0[S].2019:3250,144
[7] USP 43-NF 38[S].2020:2881,6645,6967
[8] 顾霄,朱思琪, 郑金琪. 葡萄糖酸钙注射液24种元素杂质测定方法的建立[J].药物分析杂志, 2020, 40(2): 278
GU X, ZHU SQ, ZHENG JQ. A method for the determination of 24 elemental impurities in calcium gluconate injection[J].Chin J Pharm Anal, 2020, 40(2): 278
[9] ICH Q3D. Guideline for Elemental Impurities[S].2019
[10] 中华人民共和国药典2020年版. 四部[S].2020: 43
ChP 2020.Vol Ⅳ[S].2020: 43
[11] 朱俐,赵瑜,姚尚辰,等. 药物中元素杂质检测技术研究最新进展[J].分析测试学报, 2020, 39(4): 547
ZHU L, ZHAO Y, YAO SC, et al. Research progress on detection techniques for elemental impurities in drugs[J].J Instrum Anal, 2020, 39(4): 547
[12] SILVA CSD, PINHEIRO FC, DO AMARAL CDB, et al. Determination of As, Cd, Hg and Pb in continuous use drugs and excipients by plasma-based techniques in compliance with the United States pharmacopeia requirements[J].Spectrochim Acta B,2017, 138:14
[13] 李莉,赵桂莉. 微波消解-电感耦合等离子体质谱(ICP-MS)法测定化学原料药中痕量钯含量[J].中国无机分析化学,2016,6(1): 6
LI L, ZHAO GL. Determination of trace palladium in chemical bulk drug by ICP-MS with microwave digestion[J].Chin J Inorg Anal Chem,2016,6(1): 6
[14] 李龙,于军强,于秀丽,等.地氯雷他定原料药中元素杂质的测定[J].食品与药品,2018,20(5):352
LI L, YU JQ, YU XL, et al. Determination of elemental impurities in desloratadine APIs[J].Food Drug,2018,20(5):352
[15] 马栋, 张丹, 卓先义, 等.微波消解ICP-MS法检测生物检材中汞元素[J].法医学杂志, 2011, 27(3):193
MA D, ZHANG D, ZHUO XY, et al. Determination of Hg in biological samples by inductively coupled plasma mass spectrometry[J].J Forensic Med, 2011, 27(3): 193
[16] 舒凤,张远志,王宏磊,等. ICP-MS测定汞的记忆效应的研究[J].中国卫生检验杂志, 2016, 26(2): 189
SHU F, ZHANG YZ, WANG HL, et al. Research on the memory effect of determining mercury by ICP-MS[J].Chin J Health Lab Technol, 2016, 26(2): 189