目的: 分析药用聚酯(PET)瓶中乙醛测定法现状,并对其进行标准提高。方法: 采用优化后的HS-GC法测定药用PET瓶中乙醛残留量。顶空平衡温度40 ℃,定量环温度50 ℃,传输线温度60 ℃,对照品顶空平衡时间30 min,样品顶空平衡时间8 h,进样体积1 mL;色谱柱HP-INNOWax(30 m×0.320 mm×0.25 μm),柱温50 ℃,进样口温度200 ℃,检测器温度250 ℃,载气氮气,柱流量1.5 mL·min-1,分流比30∶1。结果: 采用优化后的乙醛测定方法,乙醛对照品进样量在0.2~3.0 μg范围内呈良好线性关系,r=0.999 6;高、中、低加样回收率分别为98.6%、106.3%和100.4%。优化前后乙醛测定法测得乙醛含量结果无显著性差异。结论: 优化提高后的乙醛测定法能快速、准确地测定药用PET瓶中乙醛含量,该研究为乙醛测定法的标准提高以及药用PET瓶的质量控制提供指导意义。
Objective: To analyze the current situation of determination of acetaldehyde in pharmaceutical polyester(PET)bottle,and to improve its standard. Methods: The optimized HS-GC method was used to determine acetaldehyde residue in pharmaceutical PET bottles. Headspace equilibrium temperature was 40 ℃,loop temperature was 50 ℃,transmission line temperature was 60 ℃,headspace equilibrium time of reference substance was 30 min,headspace equilibrium time of sample was 8 h,injection volume was 1 mL;column temperature was 50 ℃,inlet temperature was 200 ℃,detector temperature was 250 ℃,carrier gas was nitrogen,column flow rate was 1.5 mL· min-1,split ratio was 30∶1. Results: Acetaldehyde has shown good linear relationship within the range of 0.2-3.0 μg(r=0.999 6). The recoveries of high,medium and low concentrations of adding were 98.6%,106.3% and 100.4%,respectively. There was no significant difference between the results of acetaldehyde content measured by acetaldehyde method before and after optimization. Conclusion: The optimized acetaldehyde determination method can determine the acetaldehyde content in the pharmaceutical PET bottles quickly and accurately. This study provides guidance for the improvement of the standard of acetaldehyde determination method and the quality control of the pharmaceutical PET bottle.
[1] YBB00282004-2015 国家药包材标准2015 年版——乙醛测定法[S].2015:283
YBB00282004-2015 National Pharmaceutical Packaging Standards—— Test for Acetaldehyde[S].2015:283
[2] YBB00102002-2015 国家药包材标准2015 年版——口服液体药用聚酯瓶[S].2015:159
YBB00102002-2015 National Pharmaceutical Packaging Standards——PET Bottles for Oral Liquid Praparation[ S].2015:159
[3] YBB00262002-2015 国家药包材标准2015 年版——口服固体药用聚酯瓶[S].2015:169
YBB00262002-2015 National Pharmaceutical Packaging Standards——PET Bottles for Oral Solid Praparation[S].2015:169
[4] 王慧利. PET 瓶中乙醛含量的测定方法及乙醛迁移量影响因素探讨[J].现代食品, 2018, 758(22):122
WANG HL.Determination of acetaldehyde content in PET bottle and study on the influencing factors of acetaldehyde migration[J].Mod Food, 2018, 758(22):122
[5] 秦静, 陈荣荣.PET 瓶装水中乙醛含量测定方法及含量影响因素[J].现代食品, 2016(1):99
QIN J, CHEN RR.Determination of acetaldehyde content in PET bottled water and its influencing factors[J].Mod Food, 2016(1):99
[6] 喻亮宇, 黄海萍.口服药用聚酯瓶标准中乙醛测定方法的改进[J].中国药品标准, 2015, 16(5):367
YU LY, HUANG HP.Improvement of acetaldehyde determination in PET bottles for oral preparations[J].Drug Stand China, 2015, 16(5):367
[7] 王琦. 瓶级聚酯切片乙醛含量分析[J].化工技术与开发, 2015, 44(10):45
WANG Q.Determination of aldehyde in bottle grade PET slice[J].Technol Develop Chem Ind, 2015, 44(10):45
[8] 陈锦国, 夏林密, 吕咏梅.顶空气相色谱法测试瓶片乙醛含量标准曲线的制作研究[J].合成技术及应用, 2013, 28(4):49
CHEN JG, XIA LM, LÜ YM.The research of producing standard curve in determining acetaldehyde content of bottle grade PET chips by headspace gas chromatography[J].Synth Technol Appl, 2013, 28(4):49
[9] 程琦. 瓶片生产中降低乙醛含量的工艺优化措施[J].科技创新导报, 2017, 30:108
CHENG Q.Process optimization measures to reduce acetaldehyde content in bottle chip production[J].Sci Technol Innov Her, 2017, 30:108
[10] 崔芬祺, 汪霞娟.顶空-气相色谱法测定水中乙醛[J].黑龙江环境通报, 2019, 43(2):42
GUI FQ, WANG XJ.Determination of acetaldehyde in water by headspace gas chromatography[J].Heilongjiang Environ J, 2019, 43(2):42
[11] 胡华峰, 张志刚, 徐蕊.关于PET 树脂及其制品中乙醛的测定技术浅析[J].饮料工业, 2019, 22(4):57
HU HF, ZHANG ZG, XU R.Brief analysis of technologies of determining in acetaldehyde content in PET resin and article[J].Bever Ind, 2019, 22(4):57
[12] 闻诚, 诸葛海涛, 费淞, 等.食品包装用PET 树脂及其成型品中乙醛含量的测定方法[J].绿色包装, 2017(1):37
WEN C, ZHUGE HT, FEI S, et al.Determination of acetaldehyde in polyethylene terephthalate resin and products used for food packaging[J].Green Pack, 2017(1):37
[13] 叶丹妮. 浅析PET 瓶胚生产中影响乙醛产生的因素[J].聚酯工业, 1994(4):30
YE DN.Factors influencing acetaldehyde production in PET bottle embryo production[J].Poly Ind, 1994(4):30
[14] 陈锦国, 龚柳柳, 夏林密, 等.PET 瓶用切片中乙醛测试标准的修订建议[J].合成技术及应用, 2017, 32(1):51
CHEN JG, GONG LL, XIA LM, et al.Suggestions for revision of acetaldehyde test standard in PET bottle slice[J].Synth Technol Appl, 2017, 32(1):51
[15] 刘容宏, 郭风, 张圣斌, 等.不同使用温度下PET 饮料瓶乙醛释放量的研究[J].塑料科技, 2017, 45(8):86
LIU RH, GUO F, ZHANG SB, et al.Study on acetaldehyde release in PET veverage bottle at different temperatures[J].Plastic Sci Technol, 2017, 45(8):86
[16] 艾莉, 陈昌松.塑料饮料瓶加工过程中的乙醛分析及其控制措施[J].食品与机械, 2015, 31(6):95
AI L, CHEN CS.Acetaldehyde analysis of beveage plastic bottle and control measures[J].Food Mach, 2015, 31(6):95
[17] USP 42-NF 37.Vol Ⅳ 42-NF 37.Vol Ⅳ[S].2020:6837