摘要

活性化合物筛选和早期药物毒性筛选是创新药物研究的起点,整合新技术的高通量筛选成为研究 热点。秀丽隐杆线虫作为一种常用的体内模式生物,既可以模拟化合物在体内的代谢变化,又可以实现药 物的高通量筛选。微流控芯片通道与线虫大小尺度相匹配,能实现线虫在芯片内分选、固定、长期培养、 自动化给药、高分辨率成像和图像自动分析等,为基于线虫的高通量高内涵药物毒性筛选研究提供了良 好的平台。本文对近年来用于药物线虫毒性测试的微流控技术进行综述,并针对此领域的未来发展提出 展望。

本文引用格式

吴佳颖, 李栋基, 陈翔, 栾洋 . 基于微流控芯片技术的秀丽隐杆线虫 药物筛选体系研究进展*[J]. 药物分析杂志, 2021 , 41(6) : 929 -942 . DOI: 10.16155/j.0254-1793.2021.06.01

Abstract

Screening of active compounds and early-stage drug toxicity screening are the basement of innovative drug researches,and high-throughput drug screening integrated with new technologies has become a popular research topic. As a powerful in vivo alternative assay system,the nematode Caenorhabditis elegansC. elegans) can not only simulate the dynamic changes of compounds in the body but also realize high-throughput exposure of drugs. Microfluidic chip is integrated with the nematodes due to its suitable size and the advantage of low reagent consumption. It can realize the following functions:sorting,immobilization,long-term cultivation,automated drug delivery,high-resolution imaging and automatic image analysis,which provides a good platform for high- throughput and high-content drug screening researches based on C. elegans. In this paper,we reviewed the microfluidic chip techniques for drug toxicology studies based on nematodes in recent years,and the future research directions were proposed.

参考文献

[1] KALETTA T,HENGARTNER MO.Finding function in novel targets:C.elegans as a model organism[J].Nat Rev Drug Discov, 2006,5(5):387
[2] HELMCKE KJ,AVILA DS,ASCHNER M.Utility of Caenorhabditis elegans in high throughput neurotoxicological research[J]. Neurotoxicol Teratol,2010,32(1):62
[3] BRENNER S.The genetics of Caenorhabditis elegans[J].Genetics,1974,77(1):71
[4] FARHAN K,HANG L.Recent advances and trends in microfluidic platforms for C.elegans biological assays[J].Annu Rev Anal Chem,2018,11(1):245
[5] DONG L,CORNAGLIA M,LEHNERT T,et al.Versatile size-dependent sorting of C.elegans nematodes and embryos using a tunable microfluidic filter structure[J].Lab Chip,2015,16(3): 574
[6] AI X,ZHUO W,LIANG Q,et al.A high-throughput device for size based separation of C.elegans developmental stages[J].Lab Chip, 2014,14(10):1746
[7] SOLVAS XCI,GEIER FM,LEROI AM,et al.High-throughput age synchronisation of Caenorhabditis elegans[J].Chem Commun, 2011,47(35):9801
[8] DONG X,SONG P,LIU X.An Automated microfluidic system for morphological measurement and size-based sorting of C.elegans[J].IEEE Trans Nanobiosci,2019,18(3):373
[9] SOFELA S,SAHLOUL S,RAFEIE M,et al.High-throughput sorting of eggs for synchronization of C.elegans in a microfluidic spiral chip[J].Lab Chip,2018,18(4):679
[10] REZAI P,SALAM S,SELVAGANAPATHY PR,et al.Electrical sorting of Caenorhabditis elegans[J].Lab Chip,2012,12(10):1831
[11] WANG X,HU R,GE A,et al.Highly efficient microfluidic sorting device for synchronizing developmental stages of C.elegans based on deflecting electrotaxis[J].Lab Chip,2015,15(11):2513
[12] YANG J,CHEN Z,YANG F,et al.A microfluidic device for rapid screening of chemotaxis-defective Caenorhabditis elegans mutants[J].Biomed Microdevices,2013,15(2):211
[13] YAN Y,NG LF,NG LT,et al.A continuous-flow C.elegans sorting system with integrated optical fiber detection and laminar flow switching[J].Lab Chip,2014,14(20):4000
[14] HU L,YE J,TAN H,et al.Quantitative analysis of Caenorhabditis elegans chemotaxis using a microfluidic device[J].Anal Chim Acta,2015,887:155
[15] LIU D,GUPTA B,SELVAGANAPATHY PR.An automated microfluidic system for screening Caenorhabditis elegans behaviors using electrotaxis[J].Biomicrofluidics,2016,10(1):14117
[16] YUAN J,RAIZEN DM,BAU HH.Propensity of undulatory swimmers,such as worms,to go against the flow[J].Proc Natl Acad Sci USA,2015,112(12):3606
17 GE A,WANG X,GE M,et al.Profile analysis of Celegans rheotaxis behavior using a microfluidic device[J].Lab Chip,2019, 19(3):475
[18] 杨剑萍,杨帆,李新春,等.基于微流控芯片的秀丽隐杆线虫的研究进展[J].生物化学与生物物理进展,2011(10):877
YANG JP,YANG F,LI XC,et al.Advances on biomedical research in Caenorhabditis elegans based on microfluidic device[J].Progress Biochem Biophys,2011(10):877
[19] HULME SE,SHE V KOP L Y AS SS,A P F E L D J,et al.A microfabricated array of clamps for immobilizing and imaging Celegans[J].Lab Chip,2007,7(11):1515
[20] BUONANNO M,GARTY G,GRAD M,et al.Microbeam irradiation of C.elegans nematode in microfluidic channels[J].Radiat Environ Biophys,2013,52(4):531
[21] SUZUKI M,HATTORI Y,SAKASHITA T,et al.Region-specific irradiation system with heavy-ion microbeam for active individuals of Caenorhabditis elegans[J].J Radiat Res,2017,58(6):881
[22] WEN H,GAO X,QIN J.Probing the anti-aging role of polydatin in
Caenorhabditis elegans on a chip[J].Integr Biol,2014,6(1):35
[23] KEIL W,KUTSCHER LM,SHAHAM S,et al.Long-term high-resolution imaging of developing C.elegans larvae with microfluidics[J].Dev Cell,2017,40(2):202
[24] KRAJNIAK J,LU H.Long-term high-resolution imaging and culture of C.elegans in chip-gel hybrid microfluidic device for developmental studies[J].Lab Chip,2010,10(14):1862
[25] CHO Y,PORTO DA,HWANG H,et al.Automated and controlled mechanical stimulation and functional imaging in vivo in C.elegans[J].Lab Chip,2004,42(8):1543
[26] BERGER S,LATTMANN ER,AEGERTER-WILMSEN T,et al.Long-term C.elegans immobilization enables high resolution developmental studies in vivo[J].Lab Chip,2018,18(9):1359
[27] KRAJNIAK J,HAO Y,MAK HY,et al.C.L.I.P.-continuous live imaging platform for direct observation of C.elegans physiological processes[J].Lab Chip,2013,13(15):2963
[28] MCCORMICK KE,G AERTNER BE,S OTTILE M,e t al.Microfluidic devices for analysis of spatial orientation behaviors in semi-restrained Caenorhabditis elegans[J].PLoS One,2011,6(10):e25710.
[29] ROHDE CB,ZENG F,GONZALEZ-RUBIO R,et al.Microfluidic system for on-chip high-throughput whole-animal sorting and screening at subcellular resolution[J].Proc Nat Acad Sci,2007, 104(35):13891
[30] ZHAO X,XU F,TANG L,et al.Microfluidic chip-based C.elegans microinjection system for investigating cell-cell communication in vivo[J].Biosens Bioelectron,2013,50(12):28
[31] CHOKSHI TV,BEN-YAKAR A,CHRONI S N.CO 2 and compressive immobilization of C.elegans on-chip[J].Lab Chip, 2009,9(1):151
[32] CHUANG HS,CHEN HY,CHEN CS,et al.Immobilization of the nematode Caenorhabditis elegans with addressable light-induced heat knockdown(ALINK)[J].Lab Chip,2013,13(15):2980
[33] CHUNG K,CRANE MM,LU H.Automated on-chip rapid microscopy,phenotyping and sorting of C.elegans[J].Nat Methods,2008,5(7):637
[34] FUEST M,NOCERA GM,MODENA MM,et al.Cryofixation during live-imaging enables millisecond time-correlated light and electron microscopy[J].J Microsc,2018,272(2):87
[35] ZHUO W,LU H,MCGRATH PT.Microfluidic platform with spatiotemporally controlled micro-environment for studying long-term C.elegans developmental arrests[J].Lab Chip,2017,17(10):1826
[36] BERGER S,LATTMANN E,AEGERTER-WILMSEN T,et al.Long-term C.elegans immobilization enables high resolution developmental studies in vivo[J].Lab Chip,2018,18(9):1359
[37] ATAKAN HB,CORNAGLIA M,MOUCHIROUD L,et al.Automated high-content phenotyping from the first larval stage till the onset of adulthood of the nematode Caenorhabditis elegans[J]. Lab Chip,2018,19(1):120
[38] ATAKAN HB,XIANG R,CORNAGLIA M,et al.Automated platform for long-term culture and high-content phenotyping of single C.elegans worms[J].Sci Rep,2019,9(1):14340
[39] 张维军,赵世坤,于洋,等.用于线虫药物筛选的微流控梯度芯片和自动化平台[J].微纳电子技术,2019,56(1):81
ZHANG WJ,ZHAO SK,YU Y,et al.Microfluidic gradient chip and automation platform for drug screening of C.elegans[J]. Micronanoelectron Technol,2019,56(1):81
[40] WANG J,FENG X,DU W,et al.Microfluidic worm-chip for in vivo analysis of neuronal activity upon dynamic chemical stimulations[J].Anal Chim Acta,2011,701(1):23
[41] WANG Y,WANG J,DU W,et al.Identification of the neuronal effects of ethanol on C.elegans by in vivo fluorescence imaging on a microfluidic chip[J].Anal Bioanal Chem,2011,399(10):3475
[42] WANG Z,LEE I,JEON TJ,et al.Micro-/nanofluidic device for tunable generation of a concentration gradient:application to Caenorhabditis elegans chemotaxis[J].Anal Bioanal Chem,2014, 406(11):2679
[43] HU L,GE A,WANG X,et al.Real-time monitoring of immune responses under pathogen invasion and drug interference by integrated microfluidic device coupled with worm-based biosensor[J].Biosens Bioelectron,2018,110:233
[44] YANG J,CHEN Z,CHING P,et al.An integrated microfluidic platform for evaluating in vivo antimicrobial activity of natural compounds using a whole-animal infection model[J].Lab Chip, 2013,13(17):3373
[45] ZHANG B,LI Y,HE Q,et al.Microfluidic platform integrated with worm-counting setup for assessing manganese toxicity[J]. Biomicrofluidics,2014,8(5):5
[46] HU L,YE J,TAN H,et al.Quantitative analysis of Caenorhabditis elegans chemotaxis using a microfluidic device[J].Anal Chim Acta,2015,887:155
[47] AHRAR S,HWANG M,DUNCAN PN,et al.Microfluidic serial dilution ladder[J].Analyst,2013,139(1):187
[48] WEN H,YU Y,ZHU G,et al.A droplet microchip with substance exchange capability for the developmental study of C.elegans[J]. Lab Chip,2015,15(8):1905
[49] AUBRY G,LU H.Droplet array for screening acute behaviour response to chemicals in Caenorhabditis elegans[J].Lab Chip, 2017,17(24):4303
[50] ABATE AR,HUNG T,MARY P,et al.High-throughput injection with microfluidics using picoinjectors[J].Proc Natl Acad Sci USA, 2010,107(45):19163
[51] CHEN Z,DENG J,ZHANG X,,et al.Anal Chim Acta.A novel micro-injection droplet microfluidic system for studying locomotive behavior responses to Cu2+ induced neurotoxin in individual C.elegans[J]. Anal Chim Acta,2020,15;1106:61
[52] LONGWELL SA,FORDYCE PM.micrio:an open-source autosampler and fraction collector for automated microfluidic input-output[J].Lab Chip,2020,20(1):93
[53] WONG BG,MANCUSO CP,SZILVIA K,et al.Precise,automated control of conditions for high-throughput growth of yeast and bacteria with evolver[J].Nat Biotechnol,2018,36:614
[54] HU PJ.Dauer[J].Wormbook,2007,61(4):1
[55] ZHUO W,LU H,MCGRATH PT.Microfluidic platform with spatiotemporally controlled micro-environment for studying long-term C.elegans developmental arrests[J].Lab Chip,2017,17(10):1826
[56] LEE KS,LEE LE,LEVINE E.HandKAchip -Hands-free killing assay on a chip[J].Sci Rep,2016,6(1):35862
[57] KELLY,TAN,PHILIP,et al.A high-throughput microfluidic microphysiological system(PREDICT-96)to recapitulate hepatocyte function in dynamic,re-circulating flow conditions[J].Lab Chip, 2019,19(9):1556
[58] KASIMATIS KR,MOERDYK-SCHAUWECKER MJ,PHILLIPS PC.Auxin-mediated sterility induction system for longevity and mating studies in Caenorhabditis elegans[J].G3(Bethesda,Md.), 2018,8(8):2655
[59] GUERRERO-RUBIO MA,HERNNDEZ-GARCA S,GARCA-CARMONA F,et al.Extension of life-span using a RNAi model and in vivo antioxidant effect of Opuntia fruit extracts and pure betalains in Caenorhabditis elegans[J].Food Chem,2018,274:840
[60] AITLHADJ L,STRZENBAUM SR.The use of FUdR can cause prolonged longevity in mutant nematodes[J].Mech Ageing Dev, 2010,131(5):364
[61] HULME SE,SHEVKOPLYAS SS,MCGUI GAN AP,et al.Lifespan-on-a-chip:microfluidic chambers for performing lifelong observation of C.elegans[J].Lab Chip,2010,10(5):589
[62] SABERI-BOSARI S,HUAYTA J,SAN-MIGUEL A.A microfluidic platform for lifelong high-resolution and high throughput imaging of subtle aging phenotypes in C.elegans[J].Lab Chip,2018,18(20):3090
[63] BANSE SA,BLUE BW,ROBINSON KJ.The stress-chip:a microfluidic platform for stress analysis in Caenorhabditis elegans[J].PLoS One,2019,14(5):e0216283
[64] CORNAGLIA M,LEHNERT T,GIJS MAM.Microfluidic systems for high-throughput and high-content screening using the nematode Caenorhabditis elegans[J].Lab Chip,2017,17(22):3736
[65] SALAM S,ANSARI A,AMON S,et al.A microfluidic phenotype analysis system reveals function of sensory and dopaminergic neuron signaling in C.elegans electrotactic swimming behavior[J].Worm, 2013,2(2):e24558
[66] ALBRECHT DR,BARGMANN CI.High-content behavioral analysis of Caenorhabditis elegans in precise spatiotemporal chemical environments[J].Nat Methods,2011,8(7):599
[67] SONG P,ZHANG W,SOBOLEVSKI A,et al.A microfluidic device for efficient chemical testing using Caenorhabditis elegans[J]. Biomed Microdevices,2015,17(2):38
[68] SZNITMAN R,GUPTA M,HAGER GD,et al.Multi-environment model estimation for motility analysis of Caenorhabditis elegans[J]. PLoS One,2010,5(7):e11631
[69] WHITE AG,LEES B,KAO H,et al.DevStaR:high-throughput quantification of C.elegans developmental stages[J].IEEE Trans Med Imaging.2013,32(10):1791
[70] JAVER A,BROWN AE,KOKKINOS I,et al.Identification of C.elegans strains using a fully convolutional neural network on behavioural dynamics[C].Computer Vision-ECCV 2018Workshops.2019:455
[71] LIU P,MARTIN RJ,DONG L.Micro-electro-fluidic grids for nematodes:a lens-less,image-sensor-less approach for on-chip tracking of nematode locomotion[J].Lab Chip,2013,13(4):650
[72] ZHANG BB,LI YB,HE QD,et al.Microfluidic platform integrated with worm-counting setup for assessing manganese toxicity[J]. Biomicrofluidics,2014,8(5):054110
[73] XIAN B,SHEN J,CHEN W,et al.WormFarm:a quantitative control and measurement device toward automated Caenorhabditis elegans aging analysis[J].Aging Cell,2013,12(3):398
[74] ATAKAN HB,CORNAGLIA M,MOUCHIROUD L,et al.Automated high-content phenotyping from the first larval stage till the onset of adulthood of the nematode Caenorhabditis elegans[J]. Lab Chip,2018,19(1):120
[75] KIM JH,LEE SH,CHA YJE,et al.C.elegans-on-a-chip for in situ and in vivo Ag nanoparticles’ uptake and toxicity assay[J].Sci Rep,2017,7:40225
[76] KOPITO RB,LEVINE E.Durable spatiotemporal surveillance of Caenorhabditis elegans response to environmental cues[J].Lab Chip,2014,14(4):764
[77] LI S,STONE HA,MURPHY CT.A microfluidic device and automatic counting system for the study of C.elegans reproductive aging[J].Lab Chip,2015,15(2):524
[78] LAGOY RC,ALBRECHT DR.Automated fluid delivery from multiwell plates to microfluidic devices for high-throughput experiments and microscopy[J].Sci Rep,2018,8(1):6217
[79] AHMED D,OZCELIK A,BOJANALA N,et al.Rotational manipulation of single cells and organisms using acoustic waves[J]. Nat Commun,2016,7:11085
[80] BERGER S,LATTMANN ER,AEGERTER-WILMSEN T,et al.Long-term C.elegans immobilization enables high resolution developmental studies in vivo[J].Lab Chip,2018,18(9): 1359
[81] SCHAFFER S,G RUBER J,N G LF,e t al .T he effect of dichloroacetate on health-and lifespan in C.elegans[J]. Biogerontology,2011,12(3):195
[82] ZHU G,YIN F,WANG L,et al.Modeling type 2 diabetes-like hyperglycemia in C.elegans on a microdevice[J].Integr Biol, 2016,8(1):30
[83] SHIRURE VS,GEORGE SC.Design considerations to minimize the impact of drug absorption in polymer-based organ-on-a-chip platforms[J].Lab Chip,2017,17(4):681
[84] NGUYEN T,JUNG SH,LEE MS,et al.Robust chemical bonding of PMMA microfluidic devices to porous PETE membranes for reliable cytotoxicity testing of drugs[J].Lab Chip,2019,19(21): 3706
文章导航

/