Objective: To meet the needs of gadolinium-based contrast agent (GBCA) analysis and testing, and to ensure drug quality and safety, a new strategy for inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) determination of 12 impurity elements (Cr, Fe, Co, Ni, Cu, V, Zn, As, Cd, Ba, Sb, and Pb) in GBCA was proposed. Methods: GBCA was diluted with 2% HNO3 and directly analyzed by ICP-MS/MS. Spectral interferences from V, Cr, Fe, Co, Ni, and Cu were eliminated using cool plasma/NH3/He reaction mode. In addition, spectral interferences from Zn, As, Cd, Ba, and Sb were eliminated using hot plasma/O2/H2 reaction mode. To evaluate the accuracy and reliability of the method, the standard reference material (NIST SRM 1643f) was analyzed by comparing the method with high-resolution ICP-MS (HR-ICP-MS), and the spiked recovery experiment was conducted. Results: Under optimized conditions, the limits of detection (LOD) of the analytes were 0.014-0.86 ng · L-1, the spiked recoveries were 96.7%-105.8%, and the RSDs were 1.6%-4.0%. The HR-ICP-MS determination values were consistent with reference values of NIST SRM 1643f. Statistical analysis showed that there was no significant difference between the measured values of the two methods at a 95% confidence level. Conclusion: The analysis method is accurate, reliable, stable and high precision. The combination of ICP-MS/MS and various reaction modes under different plasma conditions has shown promotion value for multi-element analysis in GBCA and can be extended to other fields.

Cite this article

NI Bi-yu , CHEN Lin , ZHENG Chao , HUANG Jian-hua , XIE Wen . Content determination of impurity elements in gadolinium-based contrast agent by inductively coupled plasma tandem mass spectrometry*[J]. Chinese Journal of Pharmaceutical Analysis, 2025 , 45(5) : 880 -888 . DOI: 10.16155/j.0254-1793.2024-1229

References

[1] TYLER J,FRAUM MD,DANIEL R,et al.Gadolinium-based contrast agents:a comprehensive risk assessment[J].J Magn Reson Imaging,2017,46(2):338
[2] ROGOSNITZKY M,BRANCH S.Gadolinium-based contrast agent toxicity:a review of known and proposed mechanisms[J].Biometals,2016,29:365
[3] RUDNICK MR,WAHBA IM,LEONBERG-YOO AK,et al.Risks and options with gadolinium-based contrast agents in patients with CKD:a review[J].Am J Kidney Dis,2021,77(4):517
[4] 国家食品药品监督管理总局.化学药品注射剂与药用玻璃包装容器相容性研究技术指导原则(试行)[S].2015
China Food and Drug Administration.Technical Guidance Principles for the Compatibility Study between Chemical Injection Drugs and Pharmaceutical Glass Packaging Containers(Trial)[S].2015
[5] ICH.ICH Q3D Guideline for Elemental Impurities[S].2018
[6] 中华人民共和国药典2020年版.四部[S].2020:78
ChP 2020.Vol Ⅳ[S].2020:78
[7] PINHEIRO FC,NOBREGA JA.An overview of sample preparation procedures for determination of elemental impurities in medicines[J].Microchem J,2022,175:107189
[8] 高梓真,李磊,许如玲,等.ICP-MS法测定盐酸阿芬太尼注射液中25种元素杂质的含量[J].药物分析杂志,2024,44(2):280
GAO ZZ,LI L,XU RL,et al.Determination of 25 elements impurities in alfentanil hydrochloride injection by ICP-MS[J].Chin J Pharm Anal,2024,44(2):280
[9] SHCHUKIN VM,ZHIGILEI ES,ERINA AA,et al.Validation of an ICP-MS method for the determination of mercury,lead,cadmium,and arsenic in medicinal plants and related drug preparations[J].Pharm Chem J,2020,54:968
[10] CHOI MS,RYU JS,PARK HY,et al.Precise determination of the lithium isotope ratio in geological samples using MC-ICP-MS with cool plasma[J].J Anal At Spectrom,2013,28(4):505
[11] YAMADA N.Kinetic energy discrimination in collision/reaction cell ICP-MS:theoretical review of principles and limitations[J].Spectrochim Acta B,2015,110:31
[12] HOU XL,ZHANG WC,WANG YY.Determination of femtogram-level plutonium isotopes in environmental and forensic samples with high-level uranium using chemical separation and ICP-MS/MS measurement[J].Anal Chem,2019,91(18):11553
[13] HOGMALM KJ,ZACK T,KARLSSON AKO,et al.In situ Rb-Sr and K-Ca dating by LA-ICP-MS/MS:an evaluation of N2O and SF6 as reaction gases[J].J Anal At Spectrom,2017,32(2):305
[14] KLENCSAR B,BOLEA-FERNANDEZ E,FLOREZ MR,et al.Determination of the total drug-related chlorine and bromine contents in human blood plasma using high performance liquid chromatography-tandem ICP-mass spectrometry(HPLC-ICP-MS/MS)[J].J Pharm Biomed Anal,2016,124:112
[15] YANG H,FU L,HUANG J,et al.Accurate determination of selenium in the serum with gadolinium-based magnetic resonance imaging contrasting agents by inductively coupled plasma tandem-mass spectrometry[J].Atom Spectrosc,2024,45(3):191
[16] XU Y,LI C,YU H,et al.Rapid determination of plutonium isotopes in small samples using single anion exchange separation and ICP-MS/MS measurement in NH3-He mode for sediment dating[J].Talanta,2022,240,123152
[17] COTTA AJB,ENZWEILER J.Quantification of major and trace elements in water samples by ICP-MS and collision cell to attenuate Ar and Cl-based polyatomic ions[J].J Anal At Spectrom,2009,24(10):1406
[18] RUSSELL B,GODDARD SL,MOHAMUD H,et al.Applications of hydrogen as a collision and reaction cell gas for enhanced measurement capability applied to low level stable and radioactive isotope detection using ICP-MS/MS[J].J Anal At Spectrom,2021,36(12):2704
Outlines

/